No.
Belt loop clamp standby at intermediate position:
Selection of longitudinal position
Wth ths swtch, the standby poston of the belt loop clamp n
terms of longtudnal drecton at the ntermedate standby poston
can be selected.
If the far-sde s selected, the operator has a wder space to
handle the sewng product.
Standard
Shape Nos. 3, 4, 5: Selection of travel method to second
sewing position
For the shape Nos. 3, 4 and 5, the method to move the clamp
and the garment-body presser to the second sewng poston s
selected.
Maximum sewing speed
Sewing speed of 1st stitch
In case of wth thread clamp
Sewing speed of 2nd stitch
In case of wth thread clamp
Sewing speed of 3rd stitch
In case of wth thread clamp
Sewing speed of 4th stitch
In case of wth thread clamp
Item
Far
Standard: Standard quck operaton
Operaton to reduce garment body pullng:
Select ths settng when the belt loop s
excessively floated by being pulled by the
garment body.
Operaton to prevent the belt loop from beng caught:
Select ths settng when the expanded belt loop
nterferes wth the work clamp of the machne
head or the needle.
– 88 –
Input range/
Initial value
selection range
Standard
Standard
400 to 2500
2500
400 to 1500
1000
400 to 2500
1500
400 to 2500
2500
400 to 2500
2500