0
5.1.1.3
Configuration File System Error Blink Pattern
A configuration file system error blink pattern is 4 blinks followed by a two second
pause. The 4-blink error pattern indicates that a configuration file system error has
occurred, and that the configuration file must be recreated. Refer to
Switch" on page 5-11
To recreate the configuration file, do the following:
CAUTION!
1.
Open a Telnet session and use the Shutdown command to close activity on
the switch, then power down the switch. Refer to the
on page
2.
Place the switch in maintenance mode. Press and hold the Maintenance
button for 2–4 seconds. Refer to
more information about placing the switch in maintenance mode.
3.
Establish a Telnet session with the switch using the default IP address
10.0.0.1.
4.
Enter the account name (prom) and password (prom),
5.
The following menu is displayed. Enter "6" (Remake Filesystem) and press
the Enter key to recreate the configuration file.
59042-08 A
for more information.
2 seconds
Recreating the configuration file deletes all configuration settings.
B-114.
telnet 10.0.0.1
Switch login: prom
Password:xxxx
[username@host:Itasca]% telnet 10.0.0.1
Trying 10.0.0.1...
Connected to 10.0.0.1.
Escape character is '^]'.
0)
Exit
1)
Image Unpack
2)
Reset Network Config
3)
Reset User Accounts to Default
4)
Copy Log Files
5)
Remove Switch Config
6)
Remake Filesystem
7)
Reset Switch
Option: 6
5 – Diagnostics/Troubleshooting
"Shutdown Command"
"Recovering a Switch" on page 5-11
POST Diagnostics
"Recovering a
for
5-3
Need help?
Do you have a question about the SANbox2-8c and is the answer not in the manual?
Questions and answers