Fatal Post Error Blink Pattern; Configuration File System Error Blink Pattern - Qlogic SANbox 3810 Installation Manual

Fibre channel switch
Hide thumbs Also See for SANbox 3810:
Table of Contents

Advertisement

Diagnostics/Troubleshooting
Power-On Self Test Diagnostics

Fatal POST Error Blink Pattern

A system error blink pattern is 3 blinks followed by a two second pause. The
3-blink error pattern indicates that a POST failure or a system error has left the
switch inoperable. If a system error occurs, contact your authorized maintenance
provider. Momentarily press and release the Maintenance button to reset the
switch.

Configuration File System Error Blink Pattern

A configuration file system error blink pattern is 4 blinks followed by a two second
pause. The 4-blink error pattern indicates that a configuration file system error has
occurred, and that the configuration file must be restored.
To restore the switch configuration, do the following:
1.
Establish communications with the switch using Telnet. Enter one of the
following on the command line:
telnet xxx.xxx.xxx.xxx
or
telnet switchname
where xxx.xxx.xxx.xxx is the switch IP address and switchname is the switch
name associated with the IP address.
2.
A Telnet window opens prompting you for a login. Enter an account name
and password. The default account name and password are admin and
password.
3.
Open an admin session to acquire the necessary authority.
SANbox $>admin start
4.
Restore the configuration. When the restore is complete, the switch will
reset.
SANbox (admin) $>config restore
If a configuration does not exist, enter the Config Backup command, then
enter the Config Restore command.