Aborting Mbr Mode - Euphonix MixView CS3000 Software Manual

Mixview v3.0
Hide thumbs Also See for MixView CS3000:
Table of Contents

Advertisement

SIDE NOTE:
Remember that MBR mode is
only relevant if the fader
contains previously recorded
automation data. Without
automation, the first press of
the fader's punch (attention) key
will drop that fader immediately
into automation record.

Aborting MBR Mode

Punching-In
Euphonix CS3000/2000 MixView 3.0 Software Supplement
Non-motorized fader
The fader's null LEDs will begin blinking at a fast rate. This signifies that
fader is now in MBR mode.
You now have manual control of that fader and can move it to a new position
without writing over your current automation data. The fader's null LEDs will
continue to indicate relative VCA levels.
If you wish to abort MBR mode at this point, without following through to
write new automation data, you can do one of the following:
Moving Fader
1. If the Touch option is set ON, simply remove your finger from the moving
fader to abort MBR mode.
or...
2. Press the [MBR] key to deactivate it and then press the fader's punch key
or...
3. Stop your time code source by stopping tape or stopping the VTM.
Non-motorized fader
1. Press the [MBR] key to deactivate it and then press the fader's punch key
or...
2. Stop your time code source by stopping tape or stopping the VTM.
If however, you have repositioned the fader and wish to begin writing new
automation data, simply press the fader's punch key again. At this time, the
fader's null LEDs blink rate will revert to a medium rate indicating that the
fader is again writing automation data normally.
This concludes Exercise 2.