Disk Array Settings - NEC Storage Manager Configuration Setting Tool User's Manual

Table of Contents

Advertisement

Chapter 4 Setting Commands
4
.
2
.
5
4
.
2
.
5
4
.
2
.
5
(1) Cross Call Setting
Select "21. Cross Call" from the menu and input parameters as follows to perform setting for Cross Call.
Cross Call
conf:crosscall> Cross Call Mode (0:off | 1:on) [0] =
Each parameter is described below.
- Cross Call Mode
Input ON/OFF of Cross Call Function.
"1": Set the cross all function to ON (activate).
"0": Set the Cross Call function to OFF (deactivate).
(2) Auto Assignment Mode Setting
Select "22. Auto Assignment" from the menu and input parameters as follows to perform setting for an alternative
path to use in case of trouble.
Auto Assignment
conf:autoassignment> Auto Assignment Mode (0:off | 1:on) [0] =
Each parameter is described below.
- Auto Assignment Mode
Input whether or not an alternative path is used when a trouble occurs.
"0": An alternative path is not used in case of trouble.
"1": An alternative path is used in case of trouble.
* When the cross-call function is set to ON, the Auto Assignment Mode can be changed, but the function gets
invalid. The Auto Assignment Mode gets valid when the cross-call function is set to OFF.
(3) Auto Repair Mode Setting
Select "23. Auto Repair" from the menu and input parameters as follows to set the Auto Repair Mode.
Auto Repair
conf:autorepair> Auto Repair Mode (0:off | 1:on) [1] =
D
i
s
k
A
r
r
a
y
D
i
s
k
A
r
r
a
y
D
i
s
k
A
r
r
a
y
Since the two Host Directors control LDs, all the LDs can be operated.
Only an LD with ownership can be operated from the Host Director.
S
e
t
t
i
n
g
s
S
e
t
t
i
n
g
s
S
e
t
t
i
n
g
s
II-24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storage manager configuration setting tool

Table of Contents