Table 259 Change Option Operation (continued)
Item
Parallel Initial Copy
(CU)
Num. of CUs
Change Pair Option Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,[TC],Change Pair Option,,Normal end,Seq.=xxxxxx
+{M-VOL(LDKC:CU:LDEV),Fence Level,CFW, Error Level,Result}=
-{0x00:0x00:0x00,Never,Copy To R-VOL,Group,Normal End},{0x00:0x01,Never,
Copy To R-VOL,Group,Normal End},
(snip)
-(snip), Num. of Pairs=xx
[TC]
TrueCopy for Mainframe function (for IBM z/OS)
Change Pair Option
Change Pair Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 260 Change Pair Option Operation
Item
M-VOL
(LDKC:CU:LDEV)
Fence Level
CFW
Error Level
Result
Num. of Pairs
Clear SIM Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[TC],Clear SIM,,Normal end,,,Seq.=xxxxxx
[TC]
212
TC for Mainframe Function
Description
The number of parallel operation of initial copy by CU. (1 to 16)
The number of CUs set.
Description
The LDKC, CU, and LDEV numbers of the main volume where the pair option is changed
The changed fence level (the condition that MCU rejects the write operation to the main
volume)
Never: No condition, Data: S-VOL data, Status: S-VOL status
Indicates whether the setting to copy the CFW data to the remote volume is enabled
or not
Only M-VOL: Copy to main volume only is enabled
Copy To R-VOL: Copy to main and remote volume is enabled
The error level changed (handling if trouble occurs)
This value is output when the pair option of the asynchronous pair is changed only
Volume: Volume (appropriate volume only is suspended)
Group: Group (suspended by consistency group)
The result of operation
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of changed pairs
Table 260 (page