Download Print this page

Checkpaths(Fibre) Operation - HP XP20000/XP24000 Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96085, may 2011)
Hide thumbs Also See for XP20000/XP24000:

Advertisement

HP XP External Storage Software function
ChangePaths(FIBRE)
ChangePaths(FIBRE) operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 88 ChangePaths(FIBRE) Operation
Item
ExGroup
PathGroup
Result
Port
WWN
LUN
Num. of Paths
Num. of Volumes
NOTE:
The status does not change immediately after you perform the Alternate-Path operation.
As a result, errors may occur after you perform the operation.

CheckPaths(FIBRE) Operation

This logged information indicates that the CheckPaths operation was only requested, but not finished
.
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Ext Stor],CheckPaths(FIBRE),,Normal end,,,Seq.=xxxxx
+{Port,WWN,Result}=[{1A,50560E8000C3E211,Normal end},{1A,50560E8000C3E211,Normal end},
{2A,50560E8000C3E212,Normal end}],Num. of Paths=3
[Ext Stor]
HP XP External Storage Software function
CheckPaths(FIBRE)
CheckPaths(FIBRE) operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Description
The number of the external volume group and the reference number assigned to the
external volume of the external volume that the mapping path configuration has been
changed. The number on the left of a dash (-) is the external volume number and the
number on the right of the dash (-) is the reference number of the group.
The path group number of the external volume that the mapping path configuration has
been changed.
The result of the operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The port name of the external port of the local storage system.
The WWN of the Target port of the external storage system.
The LUN of the external volume.
The number of mapping path (Port-WWN-LUN) set.
The number of external volumes that the mapping path configuration has been changed.
Table 88 (page
99).
Table 89 (page
100).
CheckPaths(FIBRE) Operation
99

Advertisement

loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000