Detailed Information
Detailed information displays for this operation, as shown in
Table 52 Change Pair Option Operation
Item
P-VOL
(Port-G-ID-LUN)
Fence Level
Error Level
Result
Num. of Pairs

Delete CTG Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Cnt Ac],Delete CTG,0x00:0x00,Normal end,,,Seq.=xxxxxx
[Cnt Ac]
HP XP Continuous Access Software function
Delete CTG
Delete Consistency Group operation
0x00
This operation uses the following parameters, as shown in
Table 53 Parameters for Delete CTG Operation
Parameter
0x00:0x00
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)

Function Switch Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Cnt Ac],Function Switch,,Normal end,,,Seq.=xxxxx
+ Switch=0001 0100 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
[Cnt Ac]
HP XP Continuous Access Software function
Function Switch
Function Switch operation
68
XP Continuous Access Software Function
Description
The port number, host group number and LUN of the primary volume where the pair
option is changed sequentially.
The changed fence level (the condition that MCU rejects Write to the primary volume).
Never: No condition, Data: S-VOL data, Status: S-VOL status
The error level changed (handling if trouble occurs).
This value is output when the pair option of the asynchronous pair is changed only.
Group: Group (suspended by consistency group),
LU: LU (appropriate LU only is suspended)
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of changed pairs.
Description
The LDKC number and the consistency group (CT group) number of the consistency group
deleted.
LDKC number: 0x00 to 0x01, CT group number: 0x00 to 0x7F
Table 52 (page
68).
Table 53 (page
68).