12 XP Continuous Access Software Function

Add CTG Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Cnt Ac],Add CTG,,Normal end,,,Seq.=xxxxx
+{LDKC,CTG,Path,Offloading(s),Inflow Control,Copy Pending(min.),RCU Ready(min.)}=
{0x00,0x00,Fibre,090,Enable,05,05}
[Cnt Ac]
HP XP Continuous Access Software function
Add CTG
Add Consistency Group operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 48 Add CTG Operation
Item
LDKC
CTG
Path
Offloading(s)
Inflow Control
Copy Pending
(min.)
RCU Ready (min.)

Change Async Option Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Cnt Ac],Change Async Option,,Normal end,,,Seq.=xxxxx
+{CLPR,Rate(%),Delay Start(%),Delay Increase(%)}={00,050,030,040}
[Cnt Ac]
HP XP Continuous Access Software function
Change Async Option
Change Async Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Description
The LDKC number.
The consistency group number of the consistency group (CT group) newly registered.
The channel type of path interface.
Fibre: Fibre Channel
The value set to the monitoring time of transfer to the side file. The unit is second.
Indicates whether the inflow control to the cache is enabled or disabled.
Enable: Setting is enabled, Disable: Setting is disabled
The setting value for Time Out (Copy Pending). The unit is minute. When Time Out (Copy
Pending) is set to 0 (zero), None is output.
The setting value for Time Out (RCU ready). The unit is minute. When Time Out (RCU
ready) is set to 0 (zero), None is output.
Table 48 (page
65).
Table 49 (page
66).
Add CTG Operation
65

Advertisement

loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000