Change 1 –> Change 2: Log information is output for the Change 2 operation.
Add –> Change: Log information is output as an Add operation, but the contents of the
setting are output according to the setting of the Change operation.
If you have deleted a host group, the following operations performed for that Host Group are
not output as log information:
Changing host mode
Changing Host Group
Adding or deleting paths
Adding, changing, or deleting WWN
2
When you apply two or more settings of the same type to the subsystem at the same time, the
log information is output as one entry.
3
When you set two or more port settings, the following conditions apply:
When you perform two or more operations for one target, the log information is output as
one entry.
The log information is output in the order of the operations performed.
If you perform the following operations at the same time, the following happens:
Change 1 –> Change 2: Log information is output for the Change 2 operation.
4
When one or more settings that you have applied at one time ends abnormally, the output log
information is Error, not Warning.
5
Indicates the operation when Fibre port is selected in the Authentication Tab.
6
When you set two or more LUSE settings, the following conditions apply:
When you perform two or more operations for one target, the log information is output as
one log information file. For example, if you have created one LUSE volume and then created
another LUSE volume using the previously-created LUSE volume, the log information is output
just as Make LUSE.
The log information is output in the order of the operations performed.
If you perform the following operations at the same time, the following happens:
Create LUSE volume –> Delete LUSE volume: The operations cancel each other, and the
log information is not output.
Create LUSE volume 1 –> Create LUSE volume 2 –> Create LUSE volume 3 using LUSE
volume 1 and LUSE volume 2 –> Delete LUSE volume 3: Log information is output only for
the Create LUSE volume 1 operation and Create LUSE volume 2 operation.
7
The log information is output at the end, no matter when you perform the Cache Residency
Manager operation.
8
For information on using XP Auto LUN Software, contact HP Technical Support.
Table 317 LUN Manager Operation and Priority of Audit Log Output
Operation
Target of Operation
Delete
LU
Host Group
WWN
Disk Controller (DKC) connection
WWN
Add
LU
UUID
Priority
2
1
1
2
4
4