Download Print this page

Restore Operation - HP XP20000/XP24000 Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96085, may 2011)
Hide thumbs Also See for XP20000/XP24000:

Advertisement

Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 207 Replace Operation
Item
Parts name
SFP
Num. of SFPs
PCB
Failed
Num. of PCBs
PDEV
Copy
Diagnosis
Micro Program
Num. of PDEV
FSW
Num. of FSWs

Restore Operation

Example 1 (restoring a PCB)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Restore,,Normal end,,,Seq.=xxxxx
+PCB=[CHA-1P],Num. of PCBs=1
+PDEV=HDD00-01
Example 2 (restoring an LDEV)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Restore,,Normal end,,,Seq.=xxxxx
+PG=[1-1],Num. of PGs=1
+PG=[E1-1],Num. of PGs=1
+PG=[V1-1],Num. of PGs=1
+PG=[X1-1],Num. of PGs=1
+LDEV=[0x00:0x03:0x2f],Num. of LDEVs=1
[Maintenance]
Maintenance function
Description
The name of the parts (EPOSW, PCICON, PCIADP, DKCPANEL, PSxx, PS-xx, BATTERY-xx,
ACBOX-x, FAN-xx, TH-xx, SSVP/MN, SVP, HDDFANxx-x, BATTERY-Uxxx, BATREG-x,
FUSE-xxx, ACBOX-Uxxx, DKUPS-xxx, SVRxxx-x, SVRxxx-Ex, EXTADP, BATTERY-SBx,
SBADP, or LEDPNLxx-x) specified to be replaced.
The port where SFPs are inserted.
The number of inserted SFPs.
The mounting location of the PCB, CHA, DKA, cache memory, CM, SM, cache switch,
MIX or BASE) to be replaced.
When replacing multiple PCBs and some of the PCBs to be replaced had failures, the
mounting locations of the failed PCBs are indicated. In such case, Warning is output as
the result of the process.
NOTE:
This information is not output when there are no failed PCBs.
The number of PCBs to be replaced.
The mounting location of the PDEVs to be replaced.
The status of copy process when replacing PDEVs. This information is output only when
replacing PDEVs.
Restore Data: Data recovery from spare disk, Correction Copy: correction copy
Diagnosis is output only when INLINE skip is selected when replacing PDEVs. This
information is output only when replacing PDEVs.
Micro Program is output only when microcode update is skipped when replacing PDEVs.
This information is output only when replacing PDEVs.
The number of PDEVs to be replaced. This information is output only when easy replacing
PDEVs.
The mounting location of fibre switches to be replaced.
The number of fibre switches to be replaced.
(for an external volume)
(for a virtual volume)
(for a Dynamic Provisioning volume)
Table 207 (page
173).
Restore Operation 173

Advertisement

loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000