26 Maintenance Function
Blockade Operation
Example 1 (blocking a Cluster)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Blockade,,Normal end,,,Seq.=xxxxx
+Location=Cluster-1
Example 2 (blocking a PCB)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Blockade,,Normal end,,,Seq.=xxxxx
+PCB=[CHA-1P],Num. of PCBs=1+
PDEV=HDD00-01
Example 3 (blocking an LDEV)
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Blockade,,Normal end,,,Seq.=xxxxx
+PG=[1-1],Num. of PGs=1
+PG=[E1-1],Num. of PGs=1
+PG=[V1-1],Num. of PGs=1
+PG=[X1-1],Num. of PGs=1
+LDEV=[0x00:0x03:0x2f],Num. of LDEVs=1
[Maintenance]
Maintenance function
Blockade
Blockade operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 199 Blockade Operation
Item
Location
PCB
Num. of PCBs
PDEV
PG
Num. of PGs
LDEV
Num. of LDEVs
Correction Copy Operation
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Maintenance],Correction Copy,,Normal end,Seq.=xxxxx
+PDEV=HDD00-01
[Maintenance]
Maintenance function
Correction Copy
168 Maintenance Function
(for an external volume)
(for a virtual volume)
(for a Dynamic Provisioning volume)
Description
The cluster to be blocked.
Cluster- 1 : Block Cluster 1, Cluster-2: Block Cluster 2
The mounting location of the PCB (CHA, Disk Adapter (DKA, CM, SM, CSW, MIX or
BASE) to be blocked.
The number of PCBs to be blocked.
The mounting location of the PDEV (physical device) to be blocked.
The parity group number.
The number of parity groups.
The LDEV number.
The number of LDEVs.
Table 199 (page
168).