Download Print this page

Xp External Storage Software Function; Addvolume(Fibre) Operation - HP XP20000/XP24000 Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96085, may 2011)
Hide thumbs Also See for XP20000/XP24000:

Advertisement

19 XP External Storage Software Function

AddVolume(FIBRE) Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Ext Stor],AddVolume(FIBRE),,),,Normal end,,,Seq.=xxxxx
+{Vendor,Product,Serial,VolumeID1,VolumeID2,Device,Capa(blocks),ExGroup,PathGroup,CLPR,
Emulation,Cache,Inflow,Result}={HITACHI,9500V,28528,0001,
0000000000000000000000000000000000000000000000000000000000000000,DF600F,4294967296,
E1-1,1,0,OPEN-V,Enable,Disable,Normal end}
++{Port,WWN,LUN}=[{1A,50560E8000C3E211,0x0001},{2A,50560E8000C3E212,0x0001},
{3A,50560E8000C3E213,0x0001},{4A,50560E8000C3E214,0x0001}],Num. of Paths=4
++{LDKC:CU:LDEV,LDEVCapa(blocks),SSID}=[{0x00:0x00:0x00,96000},{0x00:0x00:0x01,96000,0x00D8}],
Num. of LDEVs=2
+{Vendor,Product,Serial,VolumeID1,VolumeID2,Device,Capa(blocks),ExGroup,PathGroup,CLPR,
Emulation,Cache,Inflow,Result}={HITACHI,9500V,28528,0001,
0000000000000000000000000000000000000000000000000000000000000000,DF600F,4294967296,
E1-1,1,0,OPEN-V,Enable,Disable,Normal end}
++{Port,WWN,LUN}=[{1A,50560E8000C3E211,0x0002},{2A,50560E8000C3E212,0x0002}],
Num. of Paths=2,
++{LDKC:CU:LDEV,LDEVCapa(blocks),SSID}=[{0x00:0x01:0x00,4294967296,0x00D8}],Num. of LDEVs=1
+Num. of Volumes=2
[Ext Stor]
HP XP External Storage Software function
AddVolume(FIBRE)
AddVolume(FIBRE) operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 84 AddVolume(FIBRE) Operation
Item
Vendor
Product
Serial
VolumeID1
VolumeID2
Device
Capa(blocks)
ExGroup
PathGroup
CLPR
Emulation
Cache
96
XP External Storage Software Function
Description
The name of the vendor of the external storage system where the mapped external volume
exists
The product name of the external storage system where the mapped external volume
exists
The serial number the external storage system where the mapped external volume exists
The identification character 1 of the mapped external volume
The identification character 2 of the mapped external volume
The device name that the mapped external volume notifies to the host
The capacity of the mapped external volume indicated by blocks
The number of the external volume group and the reference number assigned to the
external volume of the mapped external volume. The number on the left of a dash (-) is
the external volume number and the number on the right of the dash (-) is the reference
number of the group.
The path group number of the mapped external volume
The CLPR number of the mapped external volume
The emulation type of the mapped external volume
The cache mode of the mapped external volume
Enable: Enabled, Disable: Disabled
Table 84 (page
96).

Advertisement

loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000