Download Print this page

Xp Continuous Access Journal Software Function; Journal-Option Operation - HP XP20000/XP24000 Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96085, may 2011)
Hide thumbs Also See for XP20000/XP24000:

Advertisement

13 XP Continuous Access Journal Software Function

Journal-Option Operation

user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[Cnt Ac-J],Journal-Option,,Normal end,,,Seq.=xxxxx
+{LDKC,JNLG,MetaData Ratio,Extent,Data Overflow Watch(s),Inflow Control,Copy Pace,
Path Watch Time,Forward Path Watch Time,Use of Cache,Speed of Line(Mbps),
Delta resync Failure,Result}={0x00,0x00,32,32,20,No,150,30,Yes,Not Use,256,Entire,
Normal end},
-{0x00,0x01,32,32,20,No,150,30,No,Use,256,Entire,Normal end},Num. of JNL Grps=2
[Cnt Ac-J]
HP XP Continuous Access Journal Software function
Journal-Option
Journal-Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 59 Journal-Option Operation
Item
LDKC
JNLG
MetaData Ratio
Extent
Data Overflow
Watch(s)
Inflow Control
Copy Pace
Path Watch Time
Forward Path Watch
Time
Use of Cache
Speed of Line
(Mbps)
Delta resync Failure
74
XP Continuous Access Journal Software Function
Description
The LDKC number that the journal group belongs to.
The journal group number.
The ratio of the metadata to the journal data. When the ratio is 1:32, the number for
MetaData Ratio is 32.
The number of extents.
The overflow watch time of the metadata or journal data. The unit is second.
Indicates whether inflow control is executed or not.
Yes: Controlled, No: Not controlled
The speed of initial copy. 150: Low speed. 500: Medium speed. 1500: High speed
The path blockade watch period set.
The unit is minutes, hours or days.
If it is set to 30 minutes, it will be 30 (min.).
Whether to transfer the path blockade watch period set to the master journal group to
the restore journal group.
Yes: Transfer. No: Do not transfer.
Whether to store the journal data in the restore journal group in cache.
Use: Store the journal data in cache. Not used: Store the journal data in journal volume
The transfer speed of the communication line. The unit is megabits per second (Mbps).
Indicates the operation mode when Delta resync operation have failed.
Entire: Copy the entire data volume, None: Do not copy the data volume
Table 59 (page
74).

Advertisement

loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000