Designating Drives As Hotspares - Intergraph InterRAID-8e Hardware User's Manual

Enhanced disk array cabinet
Table of Contents

Advertisement

58

Designating Drives as Hotspares

Hotspares are physical drives that are powered up with the RAID drives, and usually stay in
a standby state. If a disk drive used in a RAID logical drive fails, a hotspare will
automatically take its place and the data on the failed drive is reconstructed on the hotspare.
Hotspares can be used for level 1, 3 and 5 RAID. Each MegaRAID controller supports up to
eight hotspares. There are two methods for designating physical drives as hotspares:
u
Press
F4
u
From the Objects/Physical Drive menu, select a physical drive and press
select Make Hotspare.
When you choose any configuration option, a list of all physical devices connected to the
current controller displays, as shown below:
Press the arrow keys to highlight a disk drive that has a READY indicator and press
designate the drive as a hotspare. The indicator changes to HOTSP. The second method for
designating physical drives as hotspares is to select Objects from the Management menu, and
then select Physical Drive. A physical drive selection screen will appear. Select a disk drive
and press
ENTER
while creating arrays in Easy, New or View/Add Configuration mode.
to display the action menu for the drive.
. Then,
ENTER
to
F4

Advertisement