Error: Installation aborted
Reason
One or more drives failed to spin up
in time during the power up
sequence.
Error: Drive Status LED not functioning properly
Reason
RAID SCSI cable not properly
connected.
Error: Drive Status LED blinking amber (Channel Mode LED steady amber or
blinking amber)
Reason
A disk drive assigned to a pack has
failed, or a rebuild operation is in
progress. Disk array is in a non-
fault tolerant state.
Error: Drive Status LED off (Channel Mode LED steady amber or blinking
amber)
Reason
Disk drive is missing. Disk array
not in a fault-tolerant state.
Error: Drive Status LED blinking green (Channel Mode LED steady green)
Reason
Disk drive not assigned into a pack.
Solution
First, power off the system base unit. Power off the
cabinet. Then, power on the cabinet and wait for the
beep and the drives to cycle. Power on the system
base unit.
Solution
Verify that the RAID SCSI data cable is properly
connected to the RAID controller.
Solution
Replace the failed disk drive, rebuild the disk array.
Solution
Insert a disk drive and begin an array rebuild.
Solution
Assign the disk drive to a pack, if desired; otherwise,
the hotspare will be used in the event of a disk failure.
Refer to Chapter 4, "Using the Information Control
Panel."
125
Need help?
Do you have a question about the InterRAID-8e and is the answer not in the manual?