Fan Module; Sbar Card Menu; Using The Port Card View - HP StorageWorks 2/140 - Director Switch Product Manager Manual

Director product manager user guide
Hide thumbs Also See for StorageWorks 2/140 - Director Switch:
Table of Contents

Advertisement

If a redundant card has failed, or is not installed, choosing Switchover displays an
error message explaining that two operational cards must be installed to use this
feature.

Fan Module

Double-click a cooling fan module card in the Hardware View to display the FRU
Properties dialog box with the following option:
FRU Properties—This option displays a FRU Properties dialog box for the
module.
Properties dialog box includes the FRU name, position (slot number in the
backplane), state (active, backup, or failed), part number, and serial number.

SBAR Card Menu

Right-click an SBAR card in the Hardware View to display a menu with the
following options:
FRU Properties—Choose this option to display a FRU Properties dialog box for
the card.
Properties dialog box includes the FRU name, position (slot number in the
backplane), state (active, backup, or failed), part number, and serial number.
Enable Beaconing—Choose this option to add a check mark to the check box and
enable beaconing for the SBAR card. This causes the amber LED on the card to
flash to help you locate it in the unit.
Switchover—Choose this option to display the Switchover SBAR dialog box,
which is similar to the Switchover CTP dialog box (refer to
Switchover to switch operation from the active card to the backup card. When
switchover occurs, the green LED illuminates on the backup SBAR card to
indicate that it is now the active card.
If you click the Enable Beaconing check box to add a check mark, the amber
LED beacons (blinks) on the card that was the active card before switchover.
NOTE: You must have maintenance authorization rights to access this feature.

Using the Port Card View

In the Hardware View, double-click a port card or right-click and choose Open Port
Card View to see a detailed view of the port card. In the Port Card View, colored
indicators reflect functions of the actual LEDs on the card. The table in the Port Card
View displays the port operating state and vital product information.
director product manager user guide
Figure 2–3
is an example for the power supply module. The FRU
Figure 2–3
is an example for the power supply module. The FRU
Monitoring and Managing the Director
Figure
2–9). Click
2–15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks director 2/64

Table of Contents