Using Maintenance Features
3. Set the director to offline before performing the restore function. If you click
Restore and the director is online, a message dialog displays requesting that you
turn the director offline. No action takes place when you close the dialog box. For
instructions on setting the director offline or online, refer to
page
5–4.
4. Click Restore on the Backup and Restore Configuration dialog box to copy the
backed up configuration to the nonvolatile random access memory (NV-RAM) on
the director.
If the director is already offline and you click Restore, a confirmation dialog box
displays indicating that the restore will overwrite any existing configurations
already on the director and it displays the date of the restored backup.
NOTE: The restore operation initiates an IPL.
The Export Configuration Report function accessed through the Configure
menu on the menu bar is an ASCII file of the backup performed in this section.

Reset Configuration

This feature is used to reset all configuration data for the director to factory default
values. You must have maintenance authorization rights to access this feature.
The internet protocol (IP) address will reset to the factory default value during this
procedure, you may not recover the Ethernet connection between the director and
HAFM server if you have changed the director's IP addressing from that default
value. In this case you must reenter LAN addressing, such as IP and gateway
addresses, through a terminal attached to the maintenance port.
Before using the reset configuration option, record the director's current IP address,
which displays below the icon in the HAFM application's Product View when the
view's Display Options are set to Network Address. You can also find the current IP
address through the Embedded Web Server interface.
After resetting the configuration, reset LAN addressing to the desired values through
the maintenance port or the Embedded Web Server interface.
NOTE: Use of the maintenance port is not covered in this manual. For procedures, refer to the
hp StorageWorks director 2/64 service manual for the Director 2/64 and the hp StorageWorks
director 2/140 service manual for the Director 2/140.