HP StorageWorks 2/140 - Director Switch Product Manager Manual page 79

Director product manager user guide
Hide thumbs Also See for StorageWorks 2/140 - Director Switch:
Table of Contents

Advertisement

— Incompatible operating parameters. Operating parameters, such as resource
allocation time-out values (R_A_TOV) or error-detect time-out values
(E_D_TOV), are inconsistent. Refer to
Parameters" on
— Duplicate domain IDs. Identical preferred domain IDs are configured for two
or more directors or switches. Refer to
Parameters" on
— Incompatible zoning configurations. Refer to the hp StorageWorks ha-fabric
manager user guide and the hp StorageWorks director 2/64 service manual for
more information on zoning.
— Build fabric protocol error.
— No principal switch. A principle director or switch is not defined for the
fabric.
— No response from the attached switch.
— ELP retransmission failure timeout. A director or switch with a hardware or
link failure attempted to join the fabric and transmitted multiple exchange link
protocol (ELP) frames to another director or switch. Because of the failure,
the failed director or switch did not receive responses to the ELP frames and
did not receive a FLOGI frame. The failed director or switch times out.
A port binding error may be due to an invalid WWN or nickname entry in the
Configure Ports dialog box in the Bound WWN column. Refer to
Ports" on
Reasons messages for an invalid attachment can include:
— 01 Unknown. The reason is not known.
— 02 ISL connection not allowed on this port. ISL is
connected to a port configured as an F_Port.
— 03 ELP rejected by the attached switch. This director or
switch transmitted an exchange link protocol (ELP) frame that was rejected
by the switch at the other end of the ISL.
— 04 Incompatible switch at other end of the ISL. The
switch is configured for Open Fabric mode, and the switch at the other end of
the ISL is an HP switch configured for Homogeneous mode.
— 05 External loopback adapter connected to the port. A
loopback plug is connected to the port, and no diagnostic test running.
director product manager user guide
page 3–6
for more information.
page 3–2
for more information.
page 3–9
for a description of the Configure Ports dialog box.
Monitoring and Managing the Director
"Configuring Fabric Operating
"Configuring Switch Operating
"Configuring
2–19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks director 2/64

Table of Contents