7. Lateral Movement of the Cloth Support Plate
1
2
3
4
Caution Risk of Injury!
Set the setting the lateral movement of the cloth support plate only in
the "Safe Stop" position or with the machine turned off.
Note:
Take care that a buttonhole is set as described in Chapter 1.1
"Necessary Program Settings".
Rule and Control
The clearance between proximity switch 2 and cam plate 1 may be a
max. of 0.5 mm.
When the automatic buttonhole machine is in its initial position, the
dimension X1 (groove of the needle plate mounting to the edge 5)
must be the same as dimension X2 (edge to the groove of the needle
plate mounting). In order to correctly measure the clearance, the left
and right covers of the cloth support plate must be removed.
Turn the machine on.
–
The initial position is run into.
Correction
Loosen screw 4.
–
Manually move the cloth support plate so that the dimension is the
–
same on both sides.
Tighten screw 4 again.
–
Turn the machine on.
–
The initial position is run into.
Turn the Safe Stop on.
–
Check the dimension and redo the setting, if necessary.
–
For the setting of the clearance of the proximity switch 2 to the cam
–
plate 1, loosen screws 3.
Move proximity switch 2.
–
Tighten screws 3.
–
5
3
13