33.17 Output Test

70
ATTENTION !
The turning-on of output elements can lead to collisions with other
machine elements and to damage to the automatic sewing machine.
Before any output element is turned on make sure that this cannot
collide with other components of the automatic sewing machine.
One can switch individual or several outputs in this menu.
When you are in the service menu, sequentially select the following
menu items with the arrow keys and the "OK" key:
- Test Functions
- Multitest
- Output Test
The " Output Test " menu appears.
Select the desired output with the up and down arrow keys. The
current status of the output is shown behind the output number:
-
= Output not activated
+
= Output activated
Press the "OK" key.
The output is switched over.
With output Y16 (knife), a warning appears.
Press the OK key. The knife is switched.
Output
Designation
Y1
Cloth clamps
Y2
Spread the material
Y3
Needle thread tension
Y4
Needle thread gripper
Y5
Draw forward the needle thread
Y6
Needle thread trimmer
Y7
Open the looper thread tension and draw thread forward
Y8
Looper thread trimmer depending on subclass
Y9
Needle thread catcher
Y10
Looper thread trimmer with subclass
579-121000 and 579-141000
Y11
Needle thread catcher gripper
Y12
Needle thread catcher swings to the needle
Y16
Cutting buttonholes