Error Messages - Duerkopp Adler 579 Service Instructions Manual

Automatic buttonhole machine
Table of Contents

Advertisement

34. Error Messages

No.
Description
134
Hardware error
135
Amplifier X-motor,
136
Y-motor, Z-motor
141
Sewing motor controls:
Communication
interrupted
143
Sewing motor controls:
Command buffer full
148
Sewing motor
controls:
Drive not ready
149
Sewing motor controls:
UART not ready
150
Sewing motor
controls: Hardware
error
182
False data checksum
in the data memory
201
Data not present
208
Step losses in the
209
lateral motion axis
210
Step losses in the
211
longitudinal motion
axis
212
Step losses in the
213
sewing mechanism
rotation axis
Caution Risk of Injury!
Search for and remedy errors only in the "Safe Stop" position or with
the machine turned off.
Possible cause
- Temperature too up
- Error 5V power supply
- Error 120V power supply
- Amplifier defective
- Cable connections to the Efka
controls not okay
- Efka controls defective
Internal error
- Cable connections to the Efka
controls not okay
- Efka controls defective
- CPU unit defective
- Hardware error Efka controls
- Internal error
- Synchronizer not connected
or defective
- Commutation initiator - Lead
or voltage changer faulty
- Mains voltage too down
- Blockage, motor mechanically
overloaded
- 1 revolution after initial point
run-up reset pulse not registered
or
synchronizer defective
- Parameter not present or
internal error
- Transmission temporarily
interrupted
- Belt jumped off or defective
Internal error
Lateral motion axis too sluggish or
collision of components
Longitudinal motion axis too
sluggish or collision of components
Sewing mechanism rotation axis
too sluggish or collision of
components
Error remedy
- Check the temperature
- Check the fuses on the
transformer
- Replace the amplifier
- Check the cable connections
to the sewing motor controls
- Replace the Efka controls
Contact Dürkopp-Adler Service
- Check the cable connections to
the sewing motor controls
- Replace the Efka controls
- Replace the CPU unit
- Replace the Efka controls
- Contact Dürkopp-Adler
Service
- Positionsgeberanschluß prüfen
- Check the synchronizer
connection
- Check the setting for the mains voltage
- Check the mechanics
- Check the synchronizer (clearance
to the disc)
Replace the synchronizer
- Contact Dürkopp-Adler Service
- Check the cable connection to the
Efka controls
- Check the belt
Turn the machine off and on again.
Data is automatically reset to factory
settings.
Contact Dürkopp-Adler Service
Check the mechanics
Conduct a step loss test
Check the mechanics
Conduct a step loss test
Check the mechanics
Conduct a step loss test
3
79

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents