Power Supply Solution Not Fully Redundant; 207-Invalid Memory Configuration - Dimms Must Be Installed In Pairs Or Sequentially - HP ProLiant ML350 User Manual

Generation 5
Hide thumbs Also See for ProLiant ML350:
Table of Contents

Advertisement

For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or on the HP website
(http://www.hp.com/support).
WARNING:
information in the server documentation before removing, replacing, reseating, or modifying
system components

Power Supply Solution Not Fully Redundant

Audible beeps: None
Possible cause: The minimum power supply requirement is installed, but a redundant power supply is
missing or failed.
Action: Do one of the following:
Install a power supply.
Replace failed power supplies to complete redundancy.
207-Invalid Memory Configuration - DIMMs must be installed in
pairs or sequentially
Audible beeps: 1 long, 1 short
Possible cause: The system is configured with only one FBDIMM and the system does not support single
FBDIMM mode, or multiple FBDIMMs are installed but were not installed in the proper order.
Action: Do one of the following:
Install a valid FBDIMM pair if the system does not support single channel memory mode.
Remove and install FBDIMMs in the proper order.
To avoid potential problems, ALWAYS read the warnings and cautionary
Troubleshooting 93

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents