Raidcom Add Rcu_Path; Options And Parameters; Examples; Syntax - HP StorageWorks P9000 Reference Manual

Raid manager reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Options and parameters

Option
-cu_free <serial><id><pid>
-rcu_option <mpth> <rto>
<rtt>

Examples

For the RCU for which the product number; 64034, the RAID type: P9500 and the path ID: 1 are
set, setting the options: the minimum number of paths <mpth>-4, RIO MIH time<rto>15 seconds,
and Roud trip time 20 are set.
raidcom modify rcu -cu_free 64034 R700 1 -rcu_option 4 15 20

raidcom add rcu_path

Adds logical paths to RCUs.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.

Syntax

raidcom add rcu_path -cu_free <serial#> <id> <pid> -mcu_port <port> -rcu_port <port>
Options and parameters
Option
-cu_free <serial#><id><pid>
-mcu_port <port>
-rcu_port <port>
Examples
To the RCU for which the product number; 64034, the RAID type: P9500 and the path ID: 1 are
set, adding RCU path: mcu port: CL1-A, rcu port CL1-B.
raidcom add rcu_path -cu_free 64034 R700 1 -mcu_port CL1-A -rcu_port CL1-B
Description
-cu_free <serial#> <id> <pid>
This parameter is used to specify CU free that is specified by Serial#, id#, pid#.
< id > is used to set RAID Type, and it can be specified the following strings.
XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk Array:R600,
P9500:R700
<pid> is used to set the path group ID (1-255).
This parameter is used to specify CU control parameters.
<mpth> is used to set the number of path as minimum (1–8).
<rto> is used to set the timeout value (10–100) (second) for RIO (Remote IO) setting
between MCU and RCU.
<rtt> is used to set the round trip time value (1–500) (millisecond) between MCU and
RCU.
Description
-cu_free <serial#> <id> <pid>
This parameter is used to specify CU free that is specified by Serial#, id#, pid#.
< id > is used to set RAID Type, and it can be specified the following strings.
XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk Array:R600,
P9500:R700
<pid> is used to set the path group ID (0-255).
Specifies a port number on the MCU.
Specifies a port number on the RCU (storage system port on the remote side).
Specify the port that the attribute is MCU Initiator port (MCU) or RCU Target port (RCU).
raidcom add rcu_path 183

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents