Hardware Management Task Summaries - HP Rp7410 - Server - 0 MB RAM Administrator's Manual

Server software
Hide thumbs Also See for Rp7410 - Server - 0 MB RAM:
Table of Contents

Advertisement

Table 7-1 Hardware Management Task Summaries
Task
"Powering Server
Cabinets On and Off"
"Powering Cells and I/O
Chassis On and Off"
"Turning Attention
Indicators (LEDs) On and
Off"
202
Managing Hardware Resources
Summary
• CAUTION:
Before powering off system hardware, you first must check whether it
is being used and also inspect the hardware.
• Cabinet Power Switch: use the 48-volt power switch on the front of the cabinet.
• Service Processor (MP or GSP): PE command.
See
"Powering Server Cabinets On and Off" (page
• NOTE:
Powering on a cell also powers on any I/O chassis attached to the cell, and
powering off a cell also powers off any I/O chassis attached to the cell. Powering on
or off an I/O chassis connected to a powered-on cell causes the cell to reset if the cell
located and mapped the I/O chassis during its cell boot process.
• Service Processor (MP or GSP): PE command.
• nPartition Commands: frupower command, and specify -o or -f and a cell or I/O
chassis: -o option to turn power on, -f option to turn power off, -c# for a cell (where
# is the cell number), -i #/#/# for an I/O chassis (where #/#/# is the
cabinet/bay/chassis).
• Partition Manager:
— Version 1.0 — Select an inactive cell or I/O chassis, and use the Cell Power Off
Cell or I/O Power Off I/O Chassis action (or a similar "Power On..." action).
— Version 2.0 — Select an inactive cell or I/O chassis, and use the Cell Power Off
Cell or I/O Power Off I/O Chassis action (or a similar "Power On..." action).
See
"Powering Cells and I/O Chassis On and Off" (page
• nPartition Commands: fruled command and specify -o or -f and a cabinet, cell, or
I/O chassis: -o option to blink the LED, -f option to turn off the LED, -b# for a cabinet
(where # is the cabinet number), -c# for a cell (where # is the cell number), -i #/#/#
for an I/O chassis (where #/#/# is the cabinet/bay/chassis)
HP-UX B.11.11 supports the rad command for controlling PCI card slot attention
indicators and other tasks.
HP-UX B.11.23 and HP-UX B.11.31 support the olrad command for controlling PCI
card slot attention indicators and other tasks.
• Partition Manager:
— Version 1.0 — Select a cell or I/O chassis, and use the Cell Light Cell LED or
I/O Light I/O Chassis LED action. To turn off all LEDs use the Complex Clear
All LEDs action.
— Version 2.0 — Select a cell or I/O chassis, and use the Cell Turn On Cell LED or
I/O Turn On Chassis LED action (or a similar "Turn Off..." action). To turn off
all LEDs use the Complex Clear All LEDs action.
See
"Turning Attention Indicators (LEDs) On and Off" (page
205).
206).