HP Rp7410 - Server - 0 MB RAM Administrator's Manual page 196

Server software
Hide thumbs Also See for Rp7410 - Server - 0 MB RAM:
Table of Contents

Advertisement

3.
Exit the console and service processor interfaces if finished using them.
To exit the EFI environment type ^B (Control-B); this exits the nPartition console and returns
to the service processor Main Menu. To exit the service processor, type X at the Main Menu.
Procedure 6-22 Setting Core Cell Choices (nPartition Commands)
From the command line, use the parmodify command to configure the core cell choices for an
nPartition. You also can use the parstatus -V -p# command to list the core cell choices for
an nPartition (-p# where # is the nPartition number).
NOTE:
You can remotely perform this task using remote administration options supported by
the Enhanced nPartition Commands or Partition Manager Version 2.0. Remote administration
is supported by the Partition Manager Tools Switch Complexes action and by the nPartition
command -u... -h... options or -g... -h... options.
For details see
1.
Login to a system with the nPartition commands installed.
If using remote administration features to set core cell choices, you can login to any system
with Enhanced nPartition Commands installed.
2.
Issue the parstatus -V -p# command to list the current core cell choices and core cell
use for an nPartition.
The parstatus -V -p# command list detailed status for the specified nPartition (-p#
where # is the nPartition number).
The nPartition status includes the current active core cell ("Core Cell"), and any core cell
choice settings.
The core cell choice preferences are listed by parstatus as the "Core Cell Alternate" settings
with "1" being the highest priority and "2" through "4" as the lower priority core cell choices.
# parstatus -V -p0
[Partition]
Partition Number
Partition Name
Status
IP address
Primary Boot Path
Alternate Boot Path
HA Alternate Boot Path : 0/0/2/0/0.14.0
PDC Revision
IODCH Version
CPU Speed
Core Cell
Core Cell Alternate [1]: cab0,cell0
Core Cell Alternate [2]: cab0,cell2
....
Hardware Location
=================== ============ ==== ========== ===
cab0,bay0,chassis1
cab0,bay1,chassis3
#
196
Creating and Configuring nPartitions
"Tools for Configuring nPartitions" (page
: 0
: jules00
: active
: 0.0.0.0
: 0/0/2/0/0.13.0
: 0/0/2/0/0.0.0
: 6.0
: 23664
: 552 MHz
: cab0,cell0
Usage
active
active
165).
Core Connected
Par
IO
To
Num
yes
cab0,cell0 0
yes
cab0,cell2 0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents