HP Rp7410 - Server - 0 MB RAM Administrator's Manual page 28

Server software
Hide thumbs Also See for Rp7410 - Server - 0 MB RAM:
Table of Contents

Advertisement

For details see
Service processor (MP or GSP) methods for listing hardware and nPartition status include
the following commands, which are available from the service processor Command menu.
— CP — List nPartition configurations, including all assigned cells.
— PS — List cabinet, power, cell, processor, memory, I/O, and other details.
— IO — List connections from cells to I/O chassis on HP Superdome servers.
— ID — List product and serial numbers.
EFI Shell methods (available only on HP Integrity servers) for listing hardware and nPartition
status include the following commands. Hardware and nPartition information displayed
by the EFI Shell is limited to the local nPartition.
— info sys — List the local nPartition number and active cell details.
— info io — List the I/O configuration.
— info mem — List memory details.
— info cpu — List processor details.
BCH menu methods (available only on HP 9000 servers) for listing hardware and nPartition
status include the following commands. Hardware and nPartition information displayed
by the BCH menu is limited to the local nPartition in most cases.
— Information menu, PR command — List processor configuration details.
— Information menu, ME command — List memory configuration details.
— Information menu, IO command — List I/O configuration details.
— Information menu, CID command — List complex product and serial numbers.
— Configuration menu, PD command — List the local nPartition number and name.
nPartition administration tools for listing hardware and nPartition status include the
following features.
— Partition Manager Version 1.0 — The Complex Show Complex Details action provides
complex status information; use the Cells tab, CPUs/Memory tab, I/O Chassis tab, and
Cabinet Info tab to display selected details.
— Partition Manager Version 2.0 — The following user interface features provide nPartition
and complex status:
General tab, Hardware tab, nPartitions tab, Cells tab, I/O tab, CPUs/Memory tab,
Power and Cooling tab. Also, the Complex Show Complex Details action.
— parstatus -C command — List cell configurations.
— parstatus -V -c# command — List detailed cell information.
— parstatus -I command, rad -q command on HP-UX 11i v1 (B.11.11) systems, and
olrad -q command on HP-UX 11i v2 (B.11.23) and HP-UX 11i v3 (B.11.31) systems
— List I/O chassis and card slot details.
— parstatus -B command — List server cabinet summaries for the complex.
— parstatus -V -b# command — List detailed server cabinet status.
— parstatus -X command — List product and serial numbers.
— parstatus -P command — List a configuration summary for all nPartitions.
— parstatus -V -p# command — List detailed nPartition configuration information.
— parstatus -w command — List the local nPartition number.
— frupower -d -C command or frupower -d -I command — List power status for
all cells (-C) or all I/O chassis (-I).
For further details and summaries see
28
Getting Started with nPartitions
Chapter 8 (page
223).
Table 8-1 (page
224).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents