Chapter 59
Monitoring System Processes and Logs
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 59-1
Status
Failed
Stopped
Internal failure
Diags failed
On demand
Suspended
The status of each test in each module is visible when you display any of the show system health
commands. See the

Displaying System Health

Use the show system health command to display system-related status information (see
to
Example
Example 59-17 Displays the Current Health of All Modules in the Switch
switch# show system health
Current health information for module 2.
Test
-----------------------------------------------------------------
Bootflash
EOBC
Loopback
-----------------------------------------------------------------
Current health information for module 6.
Test
-----------------------------------------------------------------
InBand
Bootflash
EOBC
Management Port
-----------------------------------------------------------------
Example 59-18 Displays the Current Health of a Specified Module
switch# show system health module 8
Current health information for module 8.
OL-18084-01, Cisco MDS NX-OS Release 4.x
OHMS Configured Status for Tests and Modules (continued)
Description
The test has failed in this module—and the state cannot be recovered.
The test has been internally stopped in this module by the Cisco NX-OS
software.
The test encountered an internal failure in this module. For example, the system
health application is not able to open a socket as part of the test procedure.
The startup diagnostics has failed for this module or interface.
The system health external-loopback or the system health internal-loopback tests
are currently running in this module. Only these two commands can be issued on
demand.
Only encountered in the MDS 9100 Series due to one oversubscribed port
moving to a E or TE port mode. If one oversubscribed port moves to this mode,
the other three oversubscribed ports in the group are suspended.
"Displaying System Health" section on page
59-22).
Frequency
5 Sec
5 Sec
5 Sec
Frequency
5 Sec
5 Sec
5 Sec
5 Sec
59-17.
Status
Action
Running
Enabled
Running
Enabled
Running
Enabled
Status
Action
Running
Enabled
Running
Enabled
Running
Enabled
Running
Enabled
Cisco MDS 9000 Family CLI Configuration Guide
Online System Health Management
Example 59-17
59-17