Displaying System Status

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Where:
Displaying System Status
Use the show system command to display system-related status information (see
Example
Example 59-7 Displays Default Switch Port States
switch# show system default switchport
System default port state is down
System default trunk mode is on
Example 59-8 Displays Error Information for a Specified ID
switch# show system error-id 0x401D0019
Error Facility: module
Error Description: Failed to stop Linecard Async Notification.
Example 59-9 Displays the System Reset Information
switch# Show system reset-reason module 5
----- reset reason for module 5 -----
1) At 224801 usecs after Fri Nov 21 16:36:40 2003
2) At 922828 usecs after Fri Nov 21 16:02:48 2003
3) At 318034 usecs after Fri Nov 21 14:03:36 2003
4) At 255842 usecs after Wed Nov 19 00:07:49 2003
The show system reset-reason command displays the following information:
Cisco MDS 9000 Family CLI Configuration Guide
59-4
2
0
0
3
0
0
4
0
0
5
0
0
MemAlloc = total memory allocated by the process.
StackBase/Ptr = process stack base and current stack pointer in hex format.
59-10).
Reason: Reset Requested by CLI command reload
Service:
Version: 1.3(1)
Reason: Reset Requested by CLI command reload
Service:
Version: 1.3(1)
Reason: Reset Requested by CLI command reload
Service:
Version: 1.3(1)
Reason: Reset Requested by CLI command reload
Service:
Version: 1.3(1)
In a Cisco MDS 9513 Director, the last four reset-reason codes for the supervisor module in slot 7
and slot 8 are displayed. If either supervisor module is absent, the reset-reason codes for that
supervisor module are not displayed.
In a Cisco MDS 9506 or Cisco MDS 9509 switch, the last four reset-reason codes for the supervisor
module in slot 5 and slot 6 are displayed. If either supervisor module is absent, the reset-reason
codes for that supervisor module are not displayed.