Chapter 54
Configuring the Embedded Event Manager
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Command
event fanabsent [fan number] time seconds
event fanbad [fan number] time seconds
event memory {critical | minor | severe}
event module-failure type failure-type
module {slot | all} count repeats [time
seconds]
event oir {fan | module | powersupply}
{anyoir | insert | remove} [number]
event policy-default count repeats [time
seconds]
event poweroverbudget
OL-18084-01, Cisco MDS NX-OS Release 4.x
Purpose
Triggers an event if a fan is removed from the
device for more than the configured time, in
seconds. The fan number range is dependent on
different switches (for example for 9513 switches
the range is from1 to 2, for 9506/9509 switches
the range is 1). The seconds range is from 10 to
64000.
Triggers an event if a fan fails for more than the
configured time, in seconds. The fan number
range is dependent on different switches (for
example for 9513 switches the range is from1 to
2, for 9506/9509 switches the range is 1). The
seconds range is from 10 to 64000.
Triggers an event if a memory threshold is
crossed.
Triggers an event if a module experiences the
failure type configured.
The slot range is dependent on different switches
(for example for 9513 switches the range is from1
to 13, for 9509 switches the range is 1 to 9). The
repeats range is from 0 to 4294967295. The
seconds range is from 0 to 4294967295.
Triggers an event if the configured device element
(fan, module, or power supply) is inserted or
removed from the device. You can optionally
configure a specific fan, module, or power supply
number. The number range is as follows:
Fan number is dependent on different
switches.
Module number is dependent on different
switches.
Power supply number range is from 1 to 2.
Uses the event configured in the system policy.
Use this option for overriding policies.
The repeats range is from 1 to 65000. The seconds
range is from 0 to 4294967295.
Triggers an event if the power budget exceeds the
capacity of the configured power supplies.
Cisco MDS 9000 Family CLI Configuration Guide
Configuring EEM
54-7