Adding Top Talker Monitors On All Switches In The Fabric (Fabric Mode) - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.2 administrator guide (5697-0016, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

where:
slotnumber
port
n
wwn | pid
The output is sorted based on the data rate of each flow. If you do not specify the number of flows to
display, the command displays the top eight flows or the total number of flows, whichever is less.
For example, to display the top 5 flows on port 7 in WWN (default) format:
perfttmon --show 7 5
To display the top flows on slot 2, port 4 on the BHP StorageWorks 4/256 SAN Director, HP
StorageWorks DC SAN Backbone Director, or HP StorageWorks DC04 SAN Director Switch in PID
format:
perfttmon --show 2/4 pid
switch:admin> perfttmon --show 2/4 pid
========================================
Src_PID
========================================
0xa90800
0xa90800

Adding Top Talker monitors on all switches in the fabric (fabric mode)

When fabric mode is enabled, you can no longer install Top Talker monitors on an F_Port unless you first
delete fabric mode.
1.
Connect to the switch and log in as admin.
2.
Remove any end-to-end monitors in the fabric, as described in
page 410. Fabric Mode Top Talker monitors and end-to-end monitors cannot both exist in the fabric.
3.
Enter the perfTTmon
perfttmon --add fabricmode
The system responds:
Before enabling fabric mode, please remove all EE monitors in the fabric
continue? (yes, y, no, n):
4.
Enter y to continue.
Top Talker monitors are added to E_Ports in the fabric and fabric mode is enabled. Any Top Talker
monitors that were already installed on F_Ports are automatically uninstalled.
If end-to-end monitors are present on the local switch, the command fails with the message:
Cannot install Fabric Mode Top Talker because EE monitor is already
present
416 Administering advanced performance monitoring
For enterprise-class platforms only (HP StorageWorks 4/256 SAN Director, HP
StorageWorks DC SAN Backbone Director, and HP StorageWorks DC04 SAN
Director Switch), the slot number.
The port number
The number of top talking flows to display, between 1 and 32. The maximum
number of flows that are actually displayed depends on the platform:
32
For HP StorageWorks 8/8 and 8/24 SAN Switches, HP StorageWorks
8/40 SAN Switch, HP StorageWorks 8/80 SAN Switch, and FC8-xx port
blades
16
For HP StorageWorks SAN Switch 4/32, HP StorageWorks 4/64 SAN
Switch, HP StorageWorks SAN Switch 4/32B, HP StorageWorks 400
Multi-Protocol Router, and FC4-xx port blades
The format of the output. The default is wwn.
Dst_PID
MB/sec
0xa05200
6.926
0xa908ef
6.872
add fabricmode command.
--
"Deleting end-to-end
monitors" on

Hide quick links: