Setting The Maximum Lsan Count - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.2 administrator guide (5697-0016, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

12.
Enter the following commands to display information about the LSANs.
• lsanZoneShow -s shows the LSAN
switch:admin> lsanzoneshow -s
Fabric ID: 2 Zone Name: lsan_zone_fabric2
Fabric ID: 75 Zone Name: lsan_zone_fabric75
• fcrPhyDevShow shows the physical devices in the LSAN.
switch:admin> fcrphydevshow
in Fabric
-----------------------------------------
Total devices displayed: 3
• fcrProxyDevShow shows the proxy devices in the LSAN.
switch:admin> fcrproxydevshow
Proxy
Created
in Fabric
----------------------------------------------------------------------------
75
2
Total devices displayed: 2
On the FC router, the host and Target A are imported, because both are defined by lsan_zone_fabric2 and
lsan_zone_fabric75. However, target B is defined by lsan_zone_fabric75 and is not imported because
lsan_zone_fabric2 does not allow it.
When a PLOGI, PDISC, or ADISC arrives at the FC router, the SID and DID of the frame are checked. If
they are LSAN-zoned at both SID and DID edge fabrics, the frame is forwarded to the DID. If they are not
zoned, only the PLOGI is dropped; for the remaining frames zoning enforcement takes place in the edge
fabrics.

Setting the maximum LSAN count

You can set the maximum number of LSAN zones, or LSAN count, that can be configured on the edge
fabrics. By default, the maximum LSAN count is set to 3000. You can increase the maximum LSAN count to
5000 without disabling the switch.
The maximum number of LSAN devices supported is 10000 (this includes both physical and proxy
devices). If you have 3000 LSAN zones but have not exceeded the 10000 device limit, you can increase
the LSAN count to 5000.
All FC routers in the same backbone fabric should have the same maximum LSAN count defined to prevent
the FC routers from running into indefinite state. Asymmetric LSAN configurations due to different maximum
LSAN counts could lead to different devices being imported on different FC routers.
1.
Enter the fcrlsancount command with no parameters to display the current LSAN limit.
switch:admin> fcrlsancount
LSAN Zone Limit 3000
2.
Enter the fcrlsancount command and specify the new LSAN zone limit.
switch:admin> fcrlsancount 5000
LSAN Zone Limit 5000
10:00:00:00:c9:2b:c9:0c
50:05:07:61:00:5b:62:ed
50:05:07:61:00:49:20:b4
10:00:00:00:c9:2b:c9:0c
50:05:07:61:00:5b:62:ed
Device
WWN
Exists
75 10:00:00:00:c9:2b:c9:0c c70000
2
50:05:07:61:00:5b:62:ed 0100ef
2
50:05:07:61:00:5b:62:ed 0100e8
WWN
50:05:07:61:00:5b:62:ed
10:00:00:00:c9:2b:c9:0c
Imported
EXIST
EXIST
EXIST
Imported
Physical
PID
Proxy
Device
Physical
PID
Exists
in Fabric
01f001
2
02f000
75
Fabric OS 6.2 administrator guide 389
State
PID
0100e8
Imported
c70000
Imported

Hide quick links:

Advertisement

Table of Contents
loading