Constraints For Fcip Fastwrite And Tape Pipelining; Fcip Fastwrite And Tape Pipelining Configurations - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.2 administrator guide (5697-0016, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Constraints for FCIP Fastwrite and Tape Pipelining

Consider the constraints described in
Table 95
Using FCIP Fastwrite and Tape Pipelining
FCIP Fastwrite
Each GbE port supports up to 2048 simultaneous
accelerated exchanges, which means a total of
2048 simultaneous exchanges combined for
Fastwrite and Tape Pipelining.
Does not affect FICON traffic
FCIP Fastwrite and FC Fastwrite are mutually
exclusive.
Does not support multiple equal-cost path
configurations (see
Pipelining
configurations").
Class 3 traffic is accelerated with Fastwrite.

FCIP Fastwrite and Tape Pipelining configurations

To help understand the supported configurations, consider the configurations shown in the two figures
below. In both cases, there are no multiple equal-cost paths. In
Fastwrite and Tape Pipelining enabled. In
multiple equal-cost path.
Figure 79
Single tunnel, Fastwrite and Tape Pipelining enabled
Table 95
"FCIP Fastwrite and Tape
Figure
Connection can be
VE-VE or VEX-VE
when configuring tunnels to use either of these features.
Tape pipelining
Each GbE port supports up to 2048 simultaneous
accelerated exchanges, which means a total of
2048 simultaneous exchanges combined for
Fastwrite and Tape Pipelining.
Does not affect FICON traffic
Tape pipelining uses FCIP Fastwrite, not FC
Fastwrite.
Does not support multiple equal-cost path
configurations or multiple non-equal-cost path
configurations (see
"FCIP Fastwrite and Tape
Pipelining
configurations").
Class 3 traffic is accelerated between host and
sequential device.
With sequential devices (tape drives), there are
1024 initiator-tape (IT) pairs per GbE port, but
2048 initiator-tape-LUN (ITL) pairs per GbE port.
The ITL pairs are shared among the IT pairs. For
example:
Two ITL pairs for each IT pair as long as the target
has two LUNs.
If a target has 32 LUNs, 32 ITL pairs for IT pairs. In
this case, only 64 IT pairs are associated with ITL
pairs.
The rest of the IT pairs are not associated to any ITL
pairs, so no Tape Pipelining is performed for those
pairs. By default, only Fastwrite-based acceleration
is performed on the unassociated pairs.
Does not support multiple non-equal-cost path
between host and sequential device
Figure
79, there is a single tunnel with
80, there are multiple tunnels, but none of them create a
Fabric OS 6.2 administrator guide 467

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents