3.
Log in to edge fabric 2 and set up the TI zone.
a. Enter the fabricShow command to display the switches in the fabric. From the output, you can
determine the front and translate domains.
E2switch:admin> fabricshow
Switch ID
-------------------------------------------------------------------------
1: fffc01 50:00:51:e3:95:36:7e:09
4: fffc04 50:00:51:e3:95:48:9f:a1
9: fffc09 10:00:00:05:1e:40:f0:7d
The Fabric has 3 switches
b. Enter the following commands to create and display a TI zone:
E2switch:admin> zone --create -t ti TI_Zone1 -p "9,2; 9,3; 9,6; 1,-1;
4,-1"
E2switch:admin> zone --show
Defined TI zone configuration:
TI Zone Name:
Port List:
Status: Activated
c. Enter the following commands to reactivate your current effective configuration and enforce the TI
zones.
E2switch:admin> cfgactvshow
Effective configuration:
cfg:
zone:
E2switch:admin> cfgenable cfg_TI
You are about to enable a new zoning configuration.
This action will replace the old zoning configuration with the
current configuration selected.
If the update includes changes to one or more traffic isolation zones, the
update may result in localized disruption to traffic on ports associated
with the traffic isolation zone changes
Do you want to enable 'cfg_TI' configuration
zone config "cfg_TI" is in effect
Updating flash ...
358 Optimizing fabric behavior
Worldwide Name
TI_Zone1
9,2; 9,3; 9,6; 1,-1; 4,-1
Failover: Enabled
cfg_TI
lsan_t_i_TI_Zone1
10:00:00:00:00:00:02:00:00
10:00:00:00:00:00:03:00:00
10:00:00:00:00:00:08:00:00
Enet IP Addr
FC IP Addr
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
10.32.72.9
0.0.0.0
(yes, y, no, n): [no] y
Name
"fcr_fd_1"
"fcr_xd_6_9"
>"E2switch"