3.
Determine whether to set up FC Router port cost operations and/or ISL or EX-Port trunking.
These options include FC Router port cost operations and setting up either ISL or EX_Port trunking. For
information about using FCR Router Port Cost operations, see
page 383 and for information on trunking setup, see
page 385.
4.
Enter the portEnable command to enable the ports that you disabled in
physically attach ISLs from the Fibre Channel Router to the edge fabric.
switch:admin> portenable 7/10
5.
Enter the portCfgShow command to view ports that are persistently disabled.
switch:admin> portcfgshow 7/10
Area Number:
Speed Level:
Trunk Port
Long Distance
VC Link Init
Locked L_Port
Locked G_Port
Disabled E_Port
ISL R_RDY Mode
RSCN Suppressed
Persistent Disable
NPIV capability
EX Port
Mirror Port
FC Fastwrite
6.
After identifying such ports, enter the portCfgPersistentEnable command to enable the port,
and then the portCfgShow command to verify that the port is enabled.
switch:admin> portcfgpersistentenable 7/10
switch:admin> portcfgshow 7/10
Area Number:
Speed Level:
Trunk Port
Long Distance
VC Link Init
Locked L_Port
Locked G_Port
Disabled E_Port
ISL R_RDY Mode
RSCN Suppressed
Persistent Disable
NPIV capability
EX Port
Mirror Port
FC Fastwrite
7.
Enter either the portCfgEXPort or portShow command to verify that each port is configured
correctly:
switch:admin> portcfgexport 7/10
380 Using the FC-FC routing service
"FC Router port cost
"Configuring EX_Port frame
74
AUTO
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
74
AUTO
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
configuration" on
trunking" on
step