Ports And Applications Used By Switches; Access Defaults - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.2 administrator guide (5697-0016, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Table 21
Blocked listener applications (continued)
Listener application HP StorageWorks 4/256 SAN
Director, HP StorageWorks DC04
SAN Director, and HP StorageWorks
DC SAN Backbone Director
enterprise-class platforms
Disabled
discard
Disabled
ftp
Block with packet filter
rexec
Block with packet filter
rsh
Block with packet filter
rlogin
Block with packet filter
time
Disabled
rstats
Disabled
rusers

Ports and applications used by switches

If you are using the FC-FC Routing Service, be aware that the secModeEnable command is not
supported in Fabric OS 6.0.0 and later.
Table 22
lists the defaults for accessing hosts, devices, switches, and zones.
Table 22

Access defaults

Item
Hosts
Devices
Switch access
Zoning
114 Configuring standard security features
HP StorageWorks 4/8 and 4/16 SAN Switches, HP
StorageWorks 8/8 and 8/24 SAN Switches, Brocade 4Gb SAN
Switch for HP p-Class BladeSystem, Brocade 4Gb SAN Switch for
HP c-Class BladeSystem, Brocade 8Gb SAN Switch for HP
BladeSystem c-Class, HP StorageWorks EVA4400 embedded
switch module, 8Gb Brocade, HP StorageWorks SAN Switch
4/32, HP StorageWorks 4/64 SAN Switch, HP StorageWorks
SAN Switch 4/32B, HP StorageWorks 8/40 SAN Switch, HP
StorageWorks 8/80 SAN Switch, and HP StorageWorks 400
Multi-Protocol Router; HP StorageWorks SAN Director 6 Port
10Gb FC blade, HP StorageWorks SAN Director 48 Port 4Gb
FC blade, HP StorageWorks 16 Port 4Gb FC Blade, HP
StorageWorks B-Series iSCSI Director Blade, HP StorageWorks
SAN Director 16 Port 8Gb FC blade, HP StorageWorks SAN
Director 32 Port 4Gb FC Blade, HP StorageWorks SAN Director
32 Port 8Gb Blade, HP StorageWorks SAN Director 48 Port
8Gb Blade, and B-Series Multi-Protocol Router Blade
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Access default
Any host can access the fabric by SNMP.
Any host can Telnet to any switch in the fabric.
Any host can establish an HTTP connection to any switch in the fabric.
Any host can establish an API connection to any switch in the fabric.
All devices can access the management server.
Any device can connect to any FC port in the fabric.
Any switch can join the fabric.
All switches in the fabric can be accessed through a serial port.
No zoning is enabled.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents