HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual page 332

Hp storageworks fabric os 6.2 administrator guide (5697-0016, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

NOTE:
If DD and DDSets are configured on the fabric, clear the DD and DDSet configurations before
enabling iSNS client services.
1.
Connect to the switch and log in.
2.
Enter the fosConfig --enable isnsc command to enable the iSNS client service:
switch:admin> fosconfig --enable isnsc
3.
Enter the fosConfig --show command to verify that the service is enabled:
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:enabled
iSNS Client service:enabled
4.
Set the IP address of the iSNS server. You can use either the IP address of the GbE port that attaches
the HP StorageWorks B-Series iSCSI Director Blade, or the server management port IP address.
Enter the isnscCfg --set command with the -m and -s options to set GbE port IP address:
switch:admin> isnsccfg --set <slot>/ge<port> -s <IP_address>
where:
• <slot> is the number of the slot where the HP StorageWorks B-Series iSCSI Director Blade is
inserted.
• ge<port> is the physical GbE port number (ge followed by 0–7, for example, ge0).
• <IP_address> is the iSNS server IP address.
The following is an example:
switch:admin> isnsccfg --set 10/ge0 -s 10.32.0.145
iSNS client configuration updated:
peering with iSNS server 10.32.0.145 on slot 10, port ge0.
Enter the isnscCfg --show command to verify that the iSNS server has been configured correctly:
switch:admin> isnsccfg --show
iSNS client is peering with iSNS server 10.32.0.145 on slot 10, port ge0. Operational
Status: Connected to iSNS server.
Enter the isnsccfg --set command with the -m and -s options to set the IP address of the iSNS
server management port rather than the GbE port:
switch:admin> isnsccfg --set -m -s <IP_address>
where <IP_address> is the iSNS server management port IP address.
The following is an example.
switch:admin> isnsccfg –set –m –s 10.33.56.105
iSNS client configuration updated: peering with iSNS server 10.33.56.105
on the management port.
5.
Enter the isnscCfg --show command to verify that the iSNS server has been configured correctly:
switch:admin> isnsccfg --show
iSNS client is peering with iSNS server 10.33.56.105 on the management
port. Operational Status: Connected to iSNS server.
6.
Enter the isnsccfg --reregister command to re-register the iSNS objects:
switch:admin> isnsccfg --reregister