Enabling The Iscsi Gateway Service; Hp Storageworks B-Series Iscsi Director Blade Ports - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.2 administrator guide (5697-0016, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

5/ 16" = 1"
A
Rev
56-0000590-01
!
ge7
ge7
ge6
ge5
ge4
G E
ge3
ge2
ge1
ge0
ge0
7
7
6
5
4
F C
3
2
1
0
0
F C 4
16IP
Figure 39

HP StorageWorks B-Series iSCSI Director Blade ports

Enabling the iSCSI gateway service

The iSCSI gateway service translates and directs SCSI traffic between an iSCSI initiator and an FC target.
This procedure explains how to enable the iSCSI gateway service on the HP StorageWorks 4/256 SAN
Director.
1.
Connect and log in to the switch.
2.
Enter the fosConfig --show command to show the current Fabric OS configuration.
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:disabled
iSNS Client service:
3.
Enter the fosConfig --enable command to enable the iSCSI gateway service.
switch:admin> fosconfig --enable iscsi
iSCSI service is enabled
4.
Verify that the iSCSI gateway service is enabled.
switch:admin> fosconfig --show
FC Routing service:disabled
iSCSI service:enabled
s c al e:
G bE ports
F C ports
40. 1
disabled
Fabric OS 6.2 administrator guide 309

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents