End-To-End Performance Monitoring; Number Of Logical Switches That Support Performance Monitors - HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual

Hp storageworks fabric os 6.2 administrator guide (5697-0016, may 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Table 79

Number of Logical Switches that support performance monitors

Platform
HP StorageWorks
DC SAN Backbone
Director
HP StorageWorks
DC04 SAN Director
Switch
HP StorageWorks
8/40 SAN Switch
HP StorageWorks
8/80 SAN Switch
Advanced Performance Monitor commands are available only to users with the admin or switchAdmin
roles. Use the perfhelp command to display a list of commands associated with Advanced Performance
Monitoring. For detailed information on these commands, see the Fabric OS Command Reference.
NOTE:
The command examples in this chapter use the slot/port syntax required by the following:
HP StorageWorks 4/256 SAN Director
HP StorageWorks DC SAN Backbone Director
HP StorageWorks DC04 SAN Director Switch platforms.
For the following, use only the port number where needed in the commands:
HP StorageWorks 4/8 and 4/16 SAN Switches
HP StorageWorks 8/8 and 8/24 SAN Switches
HP StorageWorks SAN Switch 4/32
HP StorageWorks 4/64 SAN Switch
HP StorageWorks SAN Switch 4/32B
HP StorageWorks 8/40 SAN Switch
HP StorageWorks 8/80 SAN Switch
HP StorageWorks 400 Multi-Protocol Router

End-to-end performance monitoring

End-to-end performance monitoring counts the number of words in Fibre Channel frames for a specified
Source ID (SID) and Destination ID (DID) pair. An end-to-end performance monitor includes these counts:
RX_COUNT (words in frames received at the port)
TX_COUNT (words in frames transmitted from the port)
To enable end-to-end performance monitoring, you must configure an end-to-end monitor on a port,
specifying the SID-DID pair (in hexadecimal). The monitor counts only those frames with matching the SID
and DID.
Each SID or DID has the following three fields.
Domain ID (DD)
Area ID (AA)
AL_PA (PP)
For example, the SID 0x1 18a0f denotes DD 0x1 1, AA 0x8a, and AL_PA 0x0f.
406 Administering advanced performance monitoring
Maximum number of Logical
Switches supported
8
8
3
4
Maximum number of Logical
Switches on which monitors are
supported
4
4
3
3