Imm Error Messages - IBM 7870B4U Service Manual

Problem determination and service guide
Table of Contents

Advertisement

Table 9. Methods for viewing event logs (continued)
Condition
The blade server is hung.

IMM error messages

Use this information to resolve IMM error messages.
The following table lists IMM error messages and suggested actions to correct the
detected problems.
Note: An updated list of IMM error messages and corrective actions are available
on the IBM Web site at http://www.ibm.com/systems/support/supportsite.wss/
docdisplay?lndocid=MIGR-5079338&brandind=5000008.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are CRUs and which components
are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error Code
Type
0x80010200
Error
Error Message
Expansion Module 1 (BPE3 12V
Sense) voltage under critical
threshold. Reading: X,
Threshold: Y
Action
v If DSA Preboot is installed, restart the
blade server and press F2 to start DSA
Preboot and view the event logs.
v If DSA Preboot is not installed, insert the
DSA Preboot CD and restart the blade
server to start DSA Preboot and view the
event logs.
v Alternatively, you can restart the blade
server and press F1 to start the Setup
utility and view the POST event log or
system-event log. For more information,
see "Viewing event logs through the
Setup utility" on page 103.
Action
1. If the under voltage problem is occurring on all
blade servers, look for other events in the IMM
event log related to power and resolve those
events (see "Error logs" on page 103).
2. View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3. If other modules or blades are logging the same
issue then check the system power supply,
otherwise replace the Blade PCI Express I/O
expansion unit. See "Removing an optional
expansion unit" on page 84 and "Installing an
optional expansion unit" on page 85.
105
Chapter 6. Diagnostics