v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are CRUs and which components
are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error Code
Type
0x806F050C Error
134
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Error Message
Group 1 (All DIMMs)
correctable ECC memory error
logging limit reached
Action
1. Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory error.
2. Install the affected memory modules (as indicated
by the error LEDs on the system board or the
event logs) to a different memory channel or
microprocessor (see "Installing a memory
module" on page 65 for memory population
sequence).
3. If the error occurs again on the same memory
module, replace the affected memory module.
4. (Trained service technician only) If the problem
occurs on the same DIMM connector, check the
DIMM connector. If the connector is damaged,
replace the system-board assembly (see
"Removing the system-board assembly" on page
97 and "Installing the system-board assembly" on
page 98).
5. (Trained service technician only) Remove the
affected microprocessor and check the
microprocessor socket pins for any damaged pins.
If a damage is found, replace the system-board
assembly (see "Removing the system-board
assembly" on page 97 and "Installing the
system-board assembly" on page 98).
6. (Trained Service technician only) Replace the
affected microprocessor (See "Removing a
microprocessor and heat sink" on page 90 and
"Installing a microprocessor and heat sink" on
page 94).