v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, "Parts listing," on page 41 to determine which components are CRUs and which components
are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error Code
Type
0x80010200
Error
0x80010200
Error
0x80010200
Error
106
BladeCenter HS22 Type 7870, 1936, and 1911: Problem Determination and Service Guide
Error Message
Expansion Module 1 (BPE3
12VSB Sense) voltage under
critical threshold. Reading: X,
Threshold: Y
Expansion Module 1 (BPE3 3.3V
Sense) voltage under critical
threshold. Reading: X,
Threshold: Y
System board (Planar 12V)
voltage under critical threshold.
with chassis Reading: X,
Threshold: Y
Action
1. If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events (see
"Error logs" on page 103).
2. View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3. If other modules or blades are logging the same
issue; then, check the power supply for the
BladeCenter unit.
4.
If the base blade is not logging a power issue;
then, replace the Blade PCI Express I/O
expansion unit. See "Removing an optional
expansion unit" on page 84 and "Installing an
optional expansion unit" on page 85.
1. If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events (see
"Error logs" on page 103).
2. View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3. If the base blade is not logging a power issue;
then, replace the Blade PCI Express I/O
expansion unit. See "Removing an optional
expansion unit" on page 84 and "Installing an
optional expansion unit" on page 85.
1. If the under voltage problem is occurring on all
blade servers, look for other events in the log
related to power and resolve those events (see
"Error logs" on page 103).
2. View the event log provided by the advanced
management module for your BladeCenter unit
and resolve any power related errors that might
be displayed.
3. If other modules or blades are logging the same
issue then check the power supply for the
BladeCenter unit.
4. If the error still occurs, replace the system-board
assembly (see "Removing the system-board
assembly" on page 97 and "Installing the
system-board assembly" on page 98).