11. Slide the server chassis all the way into the rack.
12. Use the rack screws (#10-32 x 3/4) to secure the chassis and rack handles into the
rack.

Tool-less Rail Rack Mount Servicing

1. To service the system, pull the system out from the rack.
2. Disconnect the power cable(s) and proceed with servicing the system.
3. When the servicing is completed, re-connect the power cable(s).
4. Pull up on the green tabs on each rail and slide the system back into the rack.
Note: Beware of cables when re-installing the system into the rack so that the cables do not get
pulled or interfered with.

Removing and Installing the Front Bezel

The front bezels are available as optional accessories for the Intel
SR1500AL. Two front bezel options are available. One is used for the standard control
panel and the other is used with the Intel
identify your front bezel. Note the orientation in the figures below - the control panel is at
the right. If you are installing a bezel on your server system, make sure you position it as
shown.

Figure 14. Front View with Bezel supporting the Standard Control Panel

Figure 15. Front View with Bezel supporting the Intel

24
®
Local Control Panel. See the diagrams below to
®
Intel
Server System SR1500AL User's Guide
®
Server System
TP02197
TP02198
®
Local Control Panel