Clearing The Cmos; Figure 63. Clear Password Jumper - Intel SR1500AL - Server System - 0 MB RAM User Manual

Server system
Hide thumbs Also See for SR1500AL - Server System - 0 MB RAM:
Table of Contents

Advertisement

2
3
J1D2
4. Wait five seconds.
5. Return the Password Clear jumper to the Password Clear Protect position, covering
pins 1 and 2.
6. Close the server chassis.
7. Reconnect the AC power and power up the server.
8. The password is now cleared and can be reset by going into BIOS setup.

Clearing the CMOS

If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need to
be used to reset the configuration RAM.
1. Power down the system and disconnect the AC power.
2. Open the server.
3. Move the jumper from the normal operation position, CMOS Clear by BMC, at
pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3.
®
Intel
Server System SR1500AL User's Guide
BMC Force
Update Mode
Disable
2
Password
Enable
Reset
3
J1D1
2
Clear
CMOS
3
J1D3

Figure 63. Clear Password Jumper