Note:
Figure 16
be oriented in a reverse direction so as to provide correct airflow through the compute
module.
20. Set the heatsink over the processor, lining up the four captive screws with the four
posts surrounding the processor.
21. Loosely screw in the captive screws on the heatsink corners in a diagonal manner
according to the numbers shown in
a. Starting with the screw at location 1, engage the screw threads by giving it two
b. Proceed to the screw at location 2 and engage the screw threads by giving it two
c. Engage screws at locations 3 and 4 by giving each screw two rotations and then
d. Repeat steps 21a through 21c by giving each screw two rotations each time until
Reinstalling components
22. Reinstall the processor air duct.
®
Intel
Compute Module MFS5520VI User Guide
illustrates the heatsink orientation for CPU 1. The heatsink over CPU 2 should
rotations in the clockwise direction and stop. (IMPORTANT: Do not fully
tighten.)
rotations and stop.
stop.
all screws are lightly tightened upto a maximum of 8 inch-lbs torque.
2
TIM

Figure 16. Installing the Heatsink

Figure 16
as follows:
3
1
4
AF003122
23