Parameters
Parameter
physicalDisk
or
physicalDisks

Start Storage Array Blink

This command identifies a storage array by turning on the indicator LED for
the storage array. Use the stop storageArray blink command to turn off the
indicator LED for the storage array.
Syntax
start storageArray blink
Parameters
None.

Start Storage Array iSCSI Refresh

This command initiates a refresh of the network address information for the
iSNS server. If the DHCP server is marginal or unresponsive, the refresh
operation can take from 2 to 3 minutes to complete.
NOTE:
This command is for IPv4 only.
Syntax
start storageArray isnsServerRefresh
Parameter
None.
NOTE:
If you used the set storageArray isnsIPv4ConfigurationMethod command to
set the configuration but did not set the configuration to DHCP, running the start
storageArray isnsServerRefresh returns an error.
Description
Identifies the enclosure and slot where the physical disk resides.
Enclosure ID values are 0 to 99. Slot ID values are 0 to 31. You
must put brackets ([ ]) around the enclosure ID value and slot
ID value.
Script Commands