Performance Tuning

Over time, as a storage array exchanges data between the hosts and physical
disks, its performance can degrade. Monitor the performance of a storage
array and make adjustments to the storage array operational settings to
improve performance.

Monitoring Performance

Monitor the performance of a storage array by using the save storageArray
performanceStats command. This command saves performance information
to a file that you can review to determine how well the storage array is
running. Table 6-1 lists the performance information saved to the file.
Table 6-1. Storage Array Performance Information
Type of Information
Devices
Total I/Os
Read Percentage
Cache Hit Percentage Percentage of reads that are fulfilled by data from the cache
Current KB/second
Maximum KB/second Highest data transfer value achieved in the current
96
Maintaining a Storage Array
Description
Devices are:
• RAID Controller Modules — The RAID controller module
in slot 0 or 1 and a list of the virtual disks owned by the
RAID controller module
• Virtual Disk — A list of the virtual disk names
• Storage Array Totals — A list of the totals for both RAID
controller modules in an active-active RAID controller
module pair, regardless if one, both, or neither are selected
for monitoring
Number of total I/Os performed since the storage array was
started
Percentage of total I/Os that are read operations (calculate
the write percentage by subtracting the read percentage from
100 percent)
rather than requiring an actual read from a physical disk
Current transfer rate in kilobytes per second (current means
the number of kilobytes per second since the last time the
polling interval elapsed, causing an update to occur)