Error
Error message
code
2829
Cannot create Array
2830
Cannot expand Array
2831
Cannot change Array Spare
2832
Invalid physical drive
2833
Invalid Spare
2834
Invalid logical drive
2836
New Logical Drive ID does not match the
next available logical drive ID.
If you are attempting to replicate a
configuration that has non-consecutive
logical drive numbers, then you must
change the script file so that the logical
drive numbers are consecutive.
2837
New Logical Drive ID already exists
2838
Cannot create Logical Drive
2839
Cannot migrate Logical Drive RAID
2841
Cannot extend Logical Drive
2842
Invalid RAID
Comment or clarification
configuration. Configure mode can only create
new arrays.
The controller will not allow a new array to be
created, either because the controller has no
unassigned physical drives attached or because
the maximum number of arrays or logical drives
has been reached already.
The Array could not be expanded, either because
the controller does not support expansion, or the
current configuration does not allow expansion to
occur on the array.
The spare state of the array could not be
changed. This error can occur when you attempt
to add or drop a spare and the current
configuration does not allow a spare state change
for the array.
A specified physical drive is not a valid physical
drive, or it cannot be placed in the array.
A specified spare is not a valid spare drive, or it
cannot be placed in the array as a spare.
The logical drive ID is not valid.
The script file specifies a logical drive ID that is
not the first unused ID in the sequence. For
example, this message appears if the controller
has only Logical Drive 1 and the script file
specifies creation of Logical Drive 3 (omitting
Logical Drive 2). A common cause of this error is
that the input file specifies nonsequential logical
drive numbers. In this case, change the logical
drive numbers in the input file so that they are
sequential.
This error occurs in Configure mode when the
logical drive ID specified in the script file already
exists in the configuration. In Configure mode,
you can create new logical drives only.
The array has no free space, or the maximum
number of logical drives has been reached
already.
The controller does not support RAID migration, or
migration is not possible with the current
controller configuration.
The controller does not support extension, or the
current controller configuration cannot be
extended. For example, extension is not possible
if the array has no free space.
The specified RAID level is invalid or is not
possible with the current physical disk and array
configuration.
HP Array Configuration Utility 88