Acu Scripting Error Messages - HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference Manual

Smart array controllers configuring arrays
Table of Contents

Advertisement

Warning
Warning message
code
4002
Chassis name is already set to this value
4003
One or more controller commands were
skipped because the controller is not
configured
4004
Using Repeat function

ACU scripting error messages

Error
Error message
code
0
2053
Too many coinciding expansion,
migration, or extension operations
2056
Controller does not support license keys
2059
Invalid license key
2064
Controller does not support SSP
2817
Invalid Action
2818
Invalid Method
2819
Invalid Controller
2821
No controllers detected
2823
Invalid Rebuild Priority
2824
Invalid Expand Priority
2825
Invalid Array
2826
Array not specified
2827
New Array ID does not match the next
available Array ID.
2828
New Array ID already exists
Comment or clarification
The chassis name is already set to the supplied
value. The command is ignored.
Certain commands require that the controller be
configured before they can be sent to the
controller.
Some commands have been ignored because
the Repeat parameter has been specified in the
input file.
Comment or clarification
No error exists. The program completed
successfully.
The new configuration requires more
transformations than are possible at one time. For
example, you cannot expand a logical volume
and transform its RAID level at the same time.
The controller does not support license key entry
or deletion.
The entered license key is not a valid license key.
The controller does not support SSP functions.
The requested actions are invalid, for example,
combining -reset with capture mode.
The method must be either Custom or Auto.
An invalid controller value was specified.
No controllers were detected. This error applies to
Input mode only.
The specified rebuild priority is not supported.
The specified expand priority is not supported.
This error also occurs if the controller does not
allow expansion, and therefore, does not support
expand priority.
The array ID is invalid.
The Array command is missing from the script file.
Some commands were found that require an
Array to be specified.
The array ID in the script file does not match the
array ID of the next available array. For example,
if the configuration has an Array A and the input
file specifies Array C (without Array B), then the
script generates this error.
The array ID specified in the script file (in
Configure mode) already exists in the
HP Array Configuration Utility 87