Access Control (Ssp) Tasks - HP 166207-B21 - Smart Array 5302/32 RAID Controller Reference Manual

Smart array controllers configuring arrays
Table of Contents

Advertisement

Splitting a mirrored array
Run the ACU GUI in offline mode. See "Configuring a server using ACU located on the SmartStart
1.
CD (on page 26)."
At the Configuration screen, select the appropriate controller from the Controller/Device menu.
2.
From the Systems and Devices tree, select the appropriate array.
3.
In the Available Tasks panel, click Split Mirrored Array.
4.
Click OK.
5.
When ACU finishes splitting the array, two logical drives appear in the Systems and Devices tree.
6.
Shut down the OS.
7.
Power down the server.
8.
With power off, remove the physical drives that constitute one of the new arrays.
9.
If you do not remove the physical drives for one of the arrays, the OS will be unable to distinguish
between the two arrays when the server is restarted, because the arrays are identical.
Power up the server.
10.
Restart the OS.
11.
Recombining a split mirrored array
Run the ACU GUI in offline mode. See "Configuring a server using ACU located on the SmartStart
1.
CD (on page 26)."
At the Configuration screen, select the appropriate controller from the Controller/Device menu.
2.
From the Systems and Devices tree, select the array to use as the source array.
3.
In the Available Tasks panel, click Re-Mirror Array.
4.
Select the array to be mirrored to the source array.
5.
This array is usually the array that was split from the original mirrored array. However, it can be any
other array of the correct size.
Click OK.
6.
When ACU finishes re-mirroring the array, restart the OS.
7.
The controller uses the rebuild process to synchronize the mirrored drives. The hard drive online LED
flashes during the rebuild process. Depending on the hard drive size and the server load, this
process can take up to 2 hours. You can boot the OS during this time, but the logical drive is not
fault-tolerant until the rebuild is complete.

Access Control (SSP) tasks

To determine if a storage system controller supports SSP, see the storage system user guide.
SSP enables you to determine which host controllers, or initiators, can access which particular logical
drives on a storage system array controller, or target. This feature prevents data corruption that can occur
when different servers with different operating systems access the same data.
SSP enables multiple servers to share logical drives connected to the same target. SSP functionality is
enabled or disabled at the target level. Administrators can name the connections between the initiators
and the targets to help identify user groups for access privileges.